Home  
AMERICA'S LARGEST DIRECT SOURCE FOR QUALITY OUTDOOR OPTICS
SEARCH
Previous  | Next
Great Synthesis of Strength, Portability, and Precision Control
Orion Sirius EQ-G GoTo Telescope Mount
Customer Rating:  
#24336
$1,149.95

Status: In Stock
Products in stock ordered by noon pacific time M-F will ship the same day

Per-Item Shipping Charge Standard Delivery $44.00 What's This?


 
Orion Sirius EQ-G GoTo Telescope Mount
  • The Sirius EQ-G supports up to a 30-lb. load for all your visual or astrophotographic applications
  • Select from among 42,900 celestial objects using the intuitive menus on the hand controller
  • Take a tour of the finest celestial showpieces with the hand controller
  • Includes an illuminated polar-axis scope, 8.3" dovetail mounting bar, and one 11-lb. counterweight
  • The tripod is remarkably sturdy with 1.75"-diameter stainless steel legs & cast-metal spreader plate

Less hefty than the Orion Atlas, but with the same drive motors, electronic features, and functionality, the Orion Sirius EQ-G supports up to a 30-lb. load for all your visual or astrophotographic applications.

With the computerized GoTo system and hand controller, the Orion Sirius EQ-G makes a terrific upgrade into the high-tech realm of effortless, electronic object acquisition! Select from among 42,900 celestial objects using the intuitive menus on the hand controller, or take a tour of the finest celestial showpieces. The internal dual-axis stepper motors slew your telescope at up to 3.4° per second.

The Orion Sirius Mount includes an illuminated polar-axis telescope, 8.3" dovetail mounting bar, and one 11-lb. counterweight. The tripod is remarkably sturdy, as evidenced by the 1.75"-diameter stainless steel legs and cast-metal spreader plate.

Requires 12-volt DC power source or AC-to-DC adapter. Weighs 32 lbs., not including counterweight.

Please note this product was not designed or intended by the manufacturer for use by a child 12 years of age or younger.

For owners of the Orion Sirius EQ-G GoTo Mount whose version of the GoTo hand controller is 3.0 or greater, the GoTo hand controller's firmware can be updated over the internet.

Updating the GoTo Hand Controller's Firmware
From version 3.0 and up, the GoTo hand controller's firmware can be updated over the internet.

System Requirements

  • GoTo hand controller version 3.0 or greater
  • Windows95 or later
  • An available RS-232 COM port on the PC
  • Computer interface cable (supplied)
  • DC power supply (7.5V to 15V @ 100mA or greater output with 2.1mm tip positive plug)

Preparing the Computer for the Update

  1. Create a folder where you will store the files necessary for the update.
  2. Click on the Download Firmware Files link below and save the Firmware Loader program to the folder you have created on your computer. You will need to download this program only once; after it is saved on your computer, only the firmware data file is needed for future updates.
  3. Download and save the firmware update date file to the folder you created. The file will be named OrionVxxxxEQ.ssf, where xxxx indicates the version number of the firmware.

Updating the GoTo Hand Controller

  1. Plug the modular plug end of the computer interface cable into the middle jack in the hand controller. Plug the serial connector end of the cable to the COM port on your PC.
  2. Press and hold down the 0 and 8 numerical buttons simultaneously, then plug the power supply into the hand controller's DC power jack. The hand controller will beep and display "SynScan Update Ver. x.x" on the LCD screen.
  3. Run the Firmware Loader program on your computer.
  4. Click on the "Browse" box and select the OrionVxxxx.ssf file location where it was saved previously on your computer.
  5. Click on the "Update" button, and the new firmware will begin loading into the hand controller. The Firmware Loader will show the progress of the update on your computer screen. It will usually take approximately 5 minutes for the new firmware to load into the hand controller. It may take significantly longer if a serial-to-USB adapter is employed on your computer.
  6. When the download is complete, the Firmware Loader will display "Update Complete".

The firmware in the computerized GoTo hand controller has now been updated. You can click on the "HC. Version" button to confirm the new version number of the firmware (and possibly the database, but the hardware version will not change with internet updates).

Note: If the error message "Can not connect to a SynScan hand control" appears on your computer, check all cable connections. Also, try closing all other computer programs that might be attempting to use the COM port.

Note: If the error message "Firmware update failed..." appears on your computer, remove the power plug from the hand controller, and then reconnect it. Now, repeat the firmware update procedure.

By default, the data communication rate between the GoTo hand controller and the computer is 115kbps. The RS-232 port on some PCs may not support this high data transfer rate. If the firmware update procedure fails after a few tries, try reducing the data transfer rate by pressing the SETUP button on the hand controller. This will reduce the data transfer rate to 9.6kbps. The controller's LCD screen will show "Lo" in the lower right hand corner to indicate the lower transfer rate setting. The firmware update procedure remains the same except it will take much longer for the firmware to load into the hand controller.

Download Firmware Files

Need Instructions?
Download the instruction manual. Requires Adobe Reader version 3.0 or higher.