Frequently Asked Questions
Click on a link below to view the answer to the question. Clicking on the link again will collapse the answer.
What is Orion’s Standard One Year Limited Warranty?
Orion warranties against defects in materials or workmanship for a period
of one year from the date of purchase for Orion brand products. This warranty is for the benefit
of the original retail purchaser only. During this warranty period
Orion Telescopes & Binoculars will repair or replace, at Orion’s
option, any warranted instrument that proves to be defective, provided
it is returned postage paid to: Orion Warranty Repair, 89 Hangar Way,
Watsonville, CA 95076. If the product is not registered, proof of
purchase (such as a copy of the original invoice) is required.
This warranty does not apply if, in Orion’s judgment, the instrument
has been abused, mishandled, or modified, nor does it apply to normal
wear and tear. This warranty gives customer’s specific legal rights,
and you may also have other rights, which vary from state to state. For
further warranty service information, contact: Customer Service
Department, Orion Telescopes & Binoculars, 89 Hangar Way,
Watsonville CA 95076; (800) 676-1343.
Some items may be covered by a warranty period shorter or longer than the standard
one year warranty. Specific warranty information is available on the product detail page of the website
How can I check the collimation of my reflector?
Collimation is the process of adjusting the telescope's mirrors so they are perfectly aligned with one another. Your telescope’s optics were aligned at the factory, and should not need much adjustment unless the telescope is handled roughly. Mirror alignment is important to ensure the peak performance of your telescope, so it should be checked regularly. Collimation is relatively easy to do and can be done in daylight. To check collimation, remove the eyepiece and look down the focuser drawtube. You should see the secondary mirror centered in the drawtube, as well as the reflection of the primary mirror centered in the secondary mirror, and the reflection of the secondary mirror (and your eye) centered in the reflection of the primary mirror. If anything is off-center, proceed with the collimation procedure. The faster the f/ratio of your telescope, the more critical the collimation accuracy.
How do I align the secondary mirror with the collimation cap?
With the collimation cap in place, look through the hole in the cap at the secondary mirror. Ignore the reflections for the time being. The secondary mirror itself should be centered in the focuser drawtube, in the direction parallel to the length of the telescope. If it isn’t, it must be adjusted. Typically, this adjustment will rarely, if ever, need to be done. It helps to adjust the secondary mirror in a brightly lit room with the telescope pointed towards a bright surface, such as white paper or wall. Also placing a piece of white paper in the telescope tube opposite the focuser (in other words, on the other side of the secondary mirror) will also be helpful in collimating the secondary mirror. Using a 2mm Allen wrench, loosen the three small alignment set screws in the center hub of the 4-vaned spider several turns. Now hold the mirror holder stationary (be careful not to touch the surface of the mirror), while turning the center screw with a Phillips head screwdriver. Turning the screw clockwise will move the secondary mirror toward the front opening of the optical tube, while turning the screw counter-clockwise will move the secondary mirror toward the primary mirror. Note: When making these adjustments, be careful not to stress the telescope's spider vanes or they may bend. When the secondary
mirror is centered in the focuser draw-tube, rotate the secondary mirror holder until the reflection of the primary mirror is as centered in the secondary mirror as possible. It may not be perfectly centered, but that is OK. Now tighten the three small alignment screws equally to secure the secondary mirror in that position. If the entire primary mirror reflection is not visible in the secondary mirror, you will need to adjust the tilt of the secondary mirror. This is done by alternately loosening one of the three alignment set screws while tightening the other two. The goal is to center the primary mirror reflection in the secondary mirror. Don’t worry that the reflection of the secondary mirror (the smallest circle, with the collimation cap “dot” in the center) is off-center. You will fix that when aligning the primary mirror. Alternative: Some people prefer to remove the primary mirror completely from the telescope when aligning the secondary mirror, especially if the primary mirror needs to be removed anyway to be center-marked. It may help to have no reflections and align the secondary on the edge of the telescope wall.
How do I align the primary mirror with the collimation cap and center-marked mirror?
The telescope’s primary mirror will need adjustment if the secondary mirror is centered under the focuser and the reflection of the primary mirror is centered in the secondary mirror, but the small reflection of the secondary mirror (with the “dot” of the collimation cap) is off-center. The tilt of the primary mirror is adjusted with the larger collimation screws on the back end of the telescope's optical tube. The other smaller screws lock the mirror’s position in place; these thumbscrews must be loosened before any collimation adjustments can be made to the primary mirror. To start, loosen the smaller thumbscrews that lock the primary mirror in place a few turns each. Use a screwdriver in the slots, if necessary. Now, try tightening or loosening one of the larger collimation screws with your fingers Look into the focuser and see if the secondary mirror reflection has moved closer to the center of the primary. You can tell this easily with the collimation cap and mirror center mark by simply watching to see if the “dot” of the collimation cap is moving closer or further away from the “ring” on the center of the primary mirror mark. When you have the dot centered as much as is possible in the ring, your primary mirror is collimated. Re-tighten the locking thumbscrews. Alternative: If you loosen one or more of the bolts too much, it won’t move the mirror. Some people prefer to pre-load the collimation screws by tightening them all down and adjust by loosening each one in turn. This way you don’t run-out of threads and have a loose collimation screw. The disadvantage to this approach is that you have completely un-collimated the scope and are starting from the beginning.
Can I center the secondary mirror under the focuser with the aid of the Orion LaserMate?
You can, but it requires marking the center of the telescope’s secondary mirror in the same way the center of the telescope's primary mirror was marked. This is generally undesirable due to the large area of the supplied collimation targets compared to the total area of the secondary mirror. Since centering the secondary mirror under the focuser is an adjustment that very rarely, if ever, needs to be done, we recommend simply making this adjustment by eye. We’ve tried it both ways and it is just as easy to do it without the Orion LaserMate.
How do I use the Orion Collimation Cap and the mirror center mark?
The Orion collimation cap is a simple cap that fits on the focuser drawtube like a dust cap, but has a hole in the center and a silver bottom. This helps center your eye so that collimation is easy to perform. Orion telescopes that have a collimation cap included also have a primary mirror that is marked with a circle at its exact center. This “center mark” allows you to achieve a precise collimation of the
primary mirror; you don’t have to guess where the center of the mirror is. You simply adjust the mirror position until the reflection of the hole in the collimation cap is centered in the ring. The center mark is
also required for best results when using other collimating devices, such as Orion’s LaserMate Collimator, obviating the need to remove the primary mirror and mark it yourself. Note: The center ring sticker need not ever be removed from the primary mirror. Because it lies directly in the shadow of the secondary mirror, its presence in no way adversely affects the optical performance of the telescope or the image quality. That might seem counterintuitive, but its true!
Is the LaserMate Collimator dangerous?
The LaserMate emits laser radiation, so it is important not to shine the beam into your or anyone’s eye. During the collimation procedure, it is also important to avoid direct reflections of the laser beam into your eye. Rather, look only at off-axis reflections to determine the position of the laser spot on the mirrors. It is safe to view the laser when it is reflected off a surface that will diffuse the light, such as the bottom surface of the LaserMate. It is also safe to view the reflection off a mirror surface as long as the beam is not directed into your eye. Because of the potential danger from the laser beam, store your LaserMate out of the reach of children.
Does the atmosphere play a role in how good the quality of the image will be?
Atmospheric conditions play a huge part in quality of viewing. In
conditions of good “seeing”, star twinkling is minimal and objects
appear steady in the eyepiece. Seeing is best over-head, worst at the
horizon. Also, seeing generally gets better after midnight, when much
of the heat absorbed by the Earth during the day has radiated off into
space. Typically, seeing conditions will be better at sites that have
an altitude over about 3000 feet. Altitude helps because it decreases
the amount of distortion causing atmosphere you are looking
through. A good way to judge if the seeing is good or not is to look at
bright stars about 40 degrees above the horizon. If the stars appear to
“twinkle”, the atmosphere is significantly distorting the incoming
light, and views at high magnifications will not appear sharp. If the
stars appear steady and do not twinkle, seeing conditions are probably
good and higher magnifications will be possible. Also, seeing
conditions are typically
poor during the day. This is because the heat from the Sun warms the
air and causes turbulence. Good “transparency” is especially important
for observing faint objects. It simply means the air is free of
moisture, smoke, and dust. These tend to scatter light, which reduces
an object’s brightness. One good way to tell if conditions are good is
by how many stars you can see with your naked eye. If you cannot see
stars of magnitude 3.5 or dimmer then conditions are poor. Magnitude is
a measure of how bright a star is, the brighter a star is, the lower
its magnitude will be. A good star to remember for this is Megrez (mag.
3.4), which is the star in the “Big Dipper” connecting the handle to
the “dipper”. If you cannot see Megrez, then you have fog, haze,
clouds, smog, light pollution or other conditions that are hindering
your viewing. Another hint: Good seeing can vary minute to minute.
Watch the planets for a while to pick-up those moments of good seeing.
How do I clean any of the optical lenses?
Any quality optical lens cleaning tissue and optical lens cleaning fluid specifically designed for multi-coated optics can be used to clean the exposed lenses of your eyepieces or finder scope. Never use regular glass cleaner or cleaning fluid designed for eyeglasses. Before cleaning with fluid and tissue, blow any loose particles off the lens with a blower bulb or compressed air. Then apply some cleaning fluid to a tissue, never directly on the optics. Wipe the lens gently in a circular motion, then remove any excess fluid with a fresh lens tissue. Oily finger-prints and smudges may be removed using this method. Use caution; rubbing too hard may scratch the lens. On larger lenses, clean only a small area at a time, using a fresh lens tissue on each area. Never reuse tissues.
Does my telescope require time to cool down?
As a general rule, telescopes should be allowed to cool down (or warm
up) before they are used. If you bring optics from a warm air to cold
air (or vice versa) without giving it time to reach thermal
equilibrium, your telescope will give you distorted views. Allow your
telescope 30 minutes to an hour to reach the temperature of the
outdoors before using. When brining your telescope from cool temperatures to warm
temperatures, leave any protective caps off until the telescope has warmed-up to prevent condensation.
Storing your telescope in the garage or shed where the temperature is
closer to the outside temperature will reduce cool down times.
How do I take solar astrophotos?
By attaching a camera body to a telescope, in effect using the scope as a telephoto lens, you can take striking photographs of the Sun. Only attempt this if the telescope is equipped with the proper solar filter. Solar filters are coated to a neutral density of 5, which reduces the light about 100,000 times. Depending on the aperture and focal length of your telescope and “seeing” conditions, you will need to experiment to find the best exposure time for your equipment. We recommend starting with an ISO rating of around 400. At prime focus, start with an exposure of about 1/250 second. Experiment with different shutter speeds. When using higher magnifications, longer exposures will generally be necessary. If you are a beginner in astrophotography and need further information, there are books available that cover this subject completely. Do not be discouraged if your first attempts at solar photography are less than desired. The Sun is very difficult to photograph because of poorer “seeing” conditions caused by unavoidable heat currents associated with daytime viewing. The highest possible resolution for any land-based telescope, regardless of location, is about 1 arc second. Ideal seeing for any location will be available less than 5% of the time. It may be some consolation to consider that your results could equal those at professional observatories, as larger apertures and location have little, if any, advantage. During bad seeing conditions, it may help to “stop down” apertures over 5" with an off-axis mask.