Free Starry Night Special Edition software and Sky Theater DVD are included with the purchase of any astronomical Orion-brand telescope. With realistic sky simulations and a myriad of features Starry Night software will help you plan your observing sessions and help you understand what you see.
Requires PC running Windows Vista or Windows XP. Requires Macintosh running OS 10.3.9 or higher. The software and DVD will be added to your order automatically.
A per-item shipping charge (in addition to the standard shipping and handling rate) applies to this product based on its size and weight. This charge varies based on the shipping method. 3 day air shipping method incurs 2nd day per-item charges.
Beginner - Telescopes suited for beginners are easy to use and maintain. Very good optical and mechanical quality. A great first telescope that will show you the moon and planets.
Intermediate -Telescopes for the intermediate user are more robust in features and performance. Excellent quality in optics and mechanics, and more complex in use. An intermediate telescope will allow an enthusiast to "grow" in the hobby.
Advanced - Advanced telescopes are high performance, with exceptional quality. They may require more commitment to use in set-up time and technical savvy. Some advanced telescopes are easy-to-use but large and heavy. An advanced telescope is a purchase for a lifetime.
Expert - Expert telescopes offer uncompromising optical and mechanical quality for the most demanding amateur astronomer. They may be technically involved or designed for specialized use, such as astrophotography or detailed deep sky observation. They carry a premium price; but are designed to provide the ultimate performance in the field.
This is a telescope for the astronomy purist who wants the pristine, high-contrast images that only a premium apochromatic refractor can deliver and the object-finding precision and convenience that only a well-made GoTo mount can offer.
The Orion Sirius 100ED EQ-G GoTo Refractor Telescope delivers images remarkably free of chromatic aberration, thanks to the FPL-53 extra-low dispersion "ED" optical glass in one of the two objective lens elements. That, combined with the 900mm focal length (f/9.0), ensures that bright stars, planets, and the lunar limb won't be marred by color fringing. What's more, the 100mm aperture gives it 56% greater light grasp than our ED80, letting you push the magnification higher to resolve finer details. The baffled, 36"-long aluminum tube is outfitted with a 2" Crayford-style focuser (with 1.25" adapter) for exceptionally smooth focusing without backlash.
The Sirius 100ED EQ-G has the stability you need to enjoy steady images at high powers. With the GoTo controller, you will never run out of fascinating targets to view. And once you get a taste of automatic, computerized pointing, you will never go back to manually "searching" for objects again! The mount's internal dual-axis stepper motors slew your telescope at up to 3.4° per second right to your target.
Other features include a charage coupled device (CCD) autoguider port for imaging, periodic error correction (PEC), backlash compensation for GoTo slewing, latitude and azimuth adjustments for polar aligning, and an illuminated polar axis scope. The tripod is remarkably sturdy, featuring extendable 1.75"-diameter stainless steel legs and a cast-metal spreader plate.
Requires 12-volt DC power source such as the Orion Dynamo or AC-to-DC adapter for use of household 110-volt power. One-year limited warranty.
Please note this product was not designed or intended by the manufacturer for use by a child 12 years of age or younger.
For owners of the Sirius EQ-G GoTo Mount whose version of the GoTo hand controller is 3.0 or greater, the GoTo hand controller's firmware can be updated over the internet.
Updating the GoTo Hand Controller's Firmware
From version 3.0 and up, the GoTo hand controller's firmware can be updated over the internet.
System Requirements
Preparing the Computer for the Update
Updating the GoTo Hand Controller
The firmware in the GoTo hand controller has now been updated. You can click on the "HC. Version" button to confirm the new version number of the firmware (and possibly the database, but the hardware version will not change with internet updates).
Note: If the error message "Can not connect to a SynScan hand control" appears on your computer, check all cable connections. Also, try closing all other computer programs that might be attempting to use the COM port.
Note: If the error message "Firmware update failed..." appears on your computer, remove the power plug from the hand controller, and then reconnect it. Now, repeat the firmware update procedure.
By default, the data communication rate between the GoTo hand controller and the computer is 115kbps. The RS-232 port on some PCs may not support this high data transfer rate. If the firmware update procedure fails after a few tries, try reducing the data transfer rate by pressing the SETUP button on the hand controller. This will reduce the data transfer rate to 9.6kbps. The controller's LCD screen will show "Lo" in the lower right hand corner to indicate the lower transfer rate setting. The firmware update procedure remains the same except it will take much longer for the firmware to load into the hand controller.
| Use | Astronomy |
| User level | Advanced |
| Optical design | Refractor |
| Optical diameter | 100mm |
| Focal length | 900mm |
| Focal ratio | f/9.0 |
| Coatings | Fully Multi-coated |
| Optics type | Air-spaced doublet |
| Glass material | Extra low dispersion FPL-53 |
| Eyepieces included | Sirius Plossl 25.0mm (1.25in.), |
| Magnification with included eyepieces | 36x |
| Resolving power | 1.16arc*sec |
| Lowest useful magnification | 16x |
| Highest useful magnification | 200x |
| Limiting stellar magnitude | 12.7 |
| Optical quality | Diffraction Limited |
| Finder scope | 8x40 |
| Focuser | 2in. Crayford |
| Diagonal | 1.25in. 90-deg Prism Star |
| Mount style | Equatorial |
| Astro-imaging capability | Lunar, planetary and long exposure |
| Dovetail bar system | Yes |
| Computerized compatibility | Go-To included |
| Alignment procedure | 3-Star Alignment, 2-Star Alignment, 1-Star Alignment |
| Number of objects in database | 42900 |
| Tracking rates | Sidereal, Solar and Lunar |
| Motor speeds | 3.4-deg/sec, 600x, 500x, 400x, 64x, 32x, 16x, 8x, 2x, 1.75x, 1.5x, 1.25x |
| Motor type | Microstep driven 1.8-degstepper motors |
| Bearing material | Sealed ball bearings |
| Power requirement | 12-volt DC - 2A (tip positive) |
| PEC | Yes |
| GPS | Sold separately |
| Backlash compensation | Yes |
| Latitude range | 20-66 |
| Setting circles | Yes |
| Polar-axis scope | Included |
| Counterweights | One 7.5 lb. |
| Available ports | RS-232, autoguider |
| Tube material | Aluminum |
| Tripod material | Steel |
| Tripod leg diameter | 1.75 in. |
| Counterweight bar length | 8 in. |
| Diameter of counterweight shaft | 18mm |
| Height range of mount/tripod | 42.00 in. - 55.00 in. |
| Length of optical tube | 36.0 in. |
| Weight, optical tube | 7.0 lbs. |
| Weight, mount/tripod | 32.0 lbs. |
| Weight, fully assembled | 50.8 lbs. |
| Additional included accessories | GoTo hand controller |
| Other features | One Element ED glass in apochromatic primary lens, Crayford focuser, Machined aluminum lens cell |
| Warranty | One year |
Click on a link below to view the answer to the question. Clicking on the link again will collapse the answer.
What is Orion’s Standard One Year Limited Warranty?Orion warranties against defects in materials or workmanship for a period
of one year from the date of purchase for Orion brand products. This warranty is for the benefit
of the original retail purchaser only. During this warranty period
Orion Telescopes & Binoculars will repair or replace, at Orion’s
option, any warranted instrument that proves to be defective, provided
it is returned postage paid to: Orion Warranty Repair, 89 Hangar Way,
Watsonville, CA 95076. If the product is not registered, proof of
purchase (such as a copy of the original invoice) is required.
This warranty does not apply if, in Orion’s judgment, the instrument
has been abused, mishandled, or modified, nor does it apply to normal
wear and tear. This warranty gives customer’s specific legal rights,
and you may also have other rights, which vary from state to state. For
further warranty service information, contact: Customer Service
Department, Orion Telescopes & Binoculars, 89 Hangar Way,
Watsonville CA 95076; (800) 676-1343.
Some items may be covered by a warranty period shorter or longer than the standard
one year warranty. Specific warranty information is available on the product detail page of the website
Before you use the finder scope, it must be precisely aligned with the telescope so they both point to exactly the same spot. Alignment is easiest to do in daylight, rather than at night under the stars. First, insert a low power telescope eyepiece (a 25mm eyepiece will work great) into the telescope’s focuser. Then point the telescope at a discrete object such as the top of a telephone pole or a street sign that is at least a quarter-mile away. Position the telescope so the target object appears in the very center of the field of view when you look into the eyepiece. Now look through the finder scope. Is the object centered on the finder scope’s crosshairs? If not, hopefully it will be visible somewhere in the field of view, so only small turns of the finder scope bracket’s alignment thumb screws will be needed. Otherwise you’ll have to make larger turns to the alignment thumb screws to redirect the aim of the finder scope. Use the alignment thumb screws to center the object on the crosshairs of the finder scope. Then look again into the telescope’s eyepiece and see if it is still centered there too. If it isn’t, repeat the entire process, making sure not to move the telescope while adjusting the alignment of the finder scope. Finder scopes can come out of alignment during transport or when removed from the telescope, so check its alignment before each observing session.
If, when looking through the finder scope, you notice that the image is
fuzzy, you will need to focus the finder scope for your eyes.
Different finder scopes focus differently; most Orion finder scopes
include a lock ring near the objective and focus as follows:
1. Loosen the lock ring that is located behind the finder’s objective
lens cell
2. Screw the objective lens cell in or out until the image appears
sharp.
3. Tighten the lock ring behind the lens cell.
If there is no lock ring the finder scope is focused by rotating the
eyepiece.
Once the finder scope is now focused it should not need focusing again
for your eyes..
Yes, but before taking this on, regardless of the orientation, the intersection of the crosshairs marks the center and that’s what important. However, should you feel the need to change the orientation of the finder scope’s crosshairs; you can do so by carefully rotating the finder scope in its bracket. Loosen the adjustment screws or pull on the tensioner (depending on the model) and rotate the finder scope tube in the bracket until the crosshairs are oriented the way you want. You should not need to rotate the finder scope tube more than 1/4 of a turn. For right-angle finder scopes, unthread the eyepiece to re-orient the crosshairs; gently turn the eyepiece until the crosshairs are oriented as you wish. You should not need to rotate the eyepiece more than 1/4 of a turn to do this. This may leave you with a loose eyepiece. If so, you can add an o-ring or shim to tighten it at the new orientation.
To calculate the magnification, or power, of a telescope with an eyepiece, simply divide the focal length of the telescope by the focal
length of the eyepiece. Magnification
= telescope focal length ÷ eyepiece focal length. For example, the Orion Sirius 100ED EQ Refractor, which has a focal length of 900mm, used in combination with the supplied 25mm eyepiece, yields a power of: 900 ÷ 25 = 36x.
It is desirable to have a range of telescope eyepieces of different focal lengths to allow viewing over a range of magnifications. It is not uncommon for an observer to own five or more eyepieces. Orion offers many different eyepieces of varying focal lengths.
See this link to the eyepiece category on our website.
Every telescope has a theoretical limit of power of about 50x per inch of aperture (i.e. 200x for the Sirius 100ED). Atmospheric conditions will limit the usefullness of magnification and cause views to become blurred. Claims of higher power by some telescope manufacturers are a misleading advertising gimmick and should be dismissed. Keep in mind that at higher powers, an image will always be dimmer and less sharp (this is a fundamental law of optics). With every doubling of magnification you lose half the image brightness and three-fourths of the image sharpness. The steadiness of the air (the “seeing”) can also limit how much magnification an image can tolerate. Always start viewing with your lowest-power (longest focal
length) eyepiece in the telescope. It’s best to begin observing with
the lowest-power eyepiece, because it will typically provide the widest
true field of view, which will make finding and centering objects much
easier After you have located and centered an object, you can try
switching to a higher-power eyepiece to ferret out more detail, if atmospheric conditions permit. If the image you see is not crisp and steady, reduce the magnification by switching to a longer focal length
eyepiece. As a general rule, a small but well-resolved image will show
more detail and provide a more enjoyable
view than a dim and fuzzy,
over-magnified image.
To determine what telescope eyepieces you need to get powers in a particular range with your telescope, see our Learning Center article: How to choose Telescope Eyepieces
Too much magnification
Keep in mind that at higher powers, an image will always be dimmer and
less sharp (this is a fundamental law of optics). The steadiness of the
air, the seeing, can also limit how much magnification an image can
tolerate. Always start viewing with your lowest-power (longest focal
length) eyepiece in the telescope. It’s best to begin observing with
the lowest-power eyepiece, because it will typically provide the widest
true field of view, which will make finding and centering objects much
easier After you have located and centered an object, you can try
switching to a higher-power eyepiece to ferret out more detail, if
atmospheric conditions permit. If the image you see is not crisp and
steady, reduce the magnification by switching to a longer focal length
telescope eyepiece. As a general rule, a small but well-resolved image
will show more detail and provide a more enjoyable view than a dim and
fuzzy, over-magnified image. As a rule of thumb, it is not recommended
to exceed 2x per mm of aperture.
Atmospheric conditions aren’t optimal.
Atmospheric conditions vary significantly from night to night, even
hour to hour . “Seeing” refers to the steadiness of the Earth’s
atmosphere at a given time. In conditions of poor seeing, atmospheric
turbulence causes objects viewed through the telescope to “boil.” If,
when you look up at the sky with just your eyes, the stars are
twinkling noticeably, the seeing is bad and you will be limited to
viewing with low powers (bad seeing affects images at high powers more
severely). Seeing is best overhead, worst at the horizon. Also, seeing
generally gets better after midnight, when much of the heat absorbed by
the Earth during the day has radiated off into space. It’s best,
although perhaps less convenient, to escape the light-polluted city sky
in favor of darker country skies.
Viewing through a glass window open or closed.
Avoid observing from indoors through an open (or closed) window,
because the temperature difference between the indoor and outdoor air,
reflections and imperfections in the glass, will cause image blurring
and distortion.
Telescope not at thermal equilibrium.
All optical instruments need time to reach “thermal equilibrium.” The
bigger the instrument and the
larger the temperature change, the more time is needed. Allow at least
a half-hour for your telescope to cool to the temperature outdoors. In
very cold climates (below freezing), it is essential to store the
telescope as cold as possible. If it has to adjust to more than a 40 degrees
temperature change, allow at least one hour. Time to adjust varies
depending on the scope type and aperture.
Make sure you are not looking
over buildings, pavement, or any other source of heat, which will
radiate away at night, causing “heat wave” disturbances that will
distort the image you see through the telescope.
Do not expect to go from a lighted house into the darkness of the outdoors at night and immediately see faint nebulas, galaxies, and star clusters—or even very many stars, for that matter. Your eyes take about 30 minutes to reach perhaps 80 percent of their full dark-adapted sensitivity. Many observers notice improvements after several hours of total darkness. As your eyes become dark-adapted, more stars will glimmer into view and you will be able to see fainter details in objects you view in your telescope. So give yourself at least a little while to get used to the dark before you begin observing. To see what you are doing in the darkness, use a red light flashlight rather than a white light. Red light does not spoil your eyes’ dark adaptation like white light does. A flashlight with a red LED light is ideal, or you can cover the front of a regular flashlight with red cellophane or paper. Beware, too, that nearby porch and streetlights and automobile headlights will spoil your night vision. Your eyes can take at least 1/2 hour to re-adjust.
The Moon, with its rocky, cratered surface, is one of the easiest and most interesting subjects to observe with your telescope. The myriad craters, rilles, and jagged mountain formations offer endless fascination. The best time to observe the Moon is during a partial phase, that is, when the Moon is not full. During partial phases, shadows cast by crater walls and mountain peaks along the border between the dark and light portions of the lunar disk highlight the surface relief. A full Moon is too bright and devoid of surface shadows to yield a pleasing view. Try using an Orion Moon filter to dim the Moon when it is too bright; it simply threads onto the bottom of the eyepiece, you’ll see much more detail.
Most deep-sky objects are very faint, so it is important that you find an observing site well away from light pollution. Take plenty of time to let your eyes adjust to the darkness. Don’t expect these objects to appear like the photographs you see in books and magazines; most will look like dim gray “ghosts.” (Our eyes are not sensitive enough to see color in deep-sky objects except in few of the brightest ones.) But as you become more experienced and your observing skills improve, you will be able to coax out more and more intricate details. And definitely use your low-power telescope eyepieces to get a wide field-of-view for the largest of the deep-sky objects.
Starhopping, as it is called by astronomers, is perhaps the simplest way to hunt down objects to view in the night sky. It entails first pointing the telescope at a star close to the object you wish to observe, and then progressing to other stars closer and closer to the object until it is in the field of view of the eyepiece. It is a very intuitive technique that has been employed for hundreds of years by professional and amateur astronomers alike. Keep in mind, as with any new task, that starhopping may seem challenging at first, but will become easier over time and with practice. To starhop, only a minimal amount of additional equipment is necessary. A star chart or atlas that shows stars to at least magnitude 5 is required. Select one that shows the positions of many deep-sky objects, so you will have a lot of options to choose from. If you do not know the positions of the constellations in the night sky, you will need to get a planisphere to identify them. Start by choosing bright objects to view. The brightness of an object is measured by its visual magnitude; the brighter an object, the lower its magnitude. Choose an object with a visual magnitude of 9 or lower. Many beginners start with the Messier objects, which represent some of the best and brightest deep-sky objects, first catalogued about 200 years ago by the French astronomer Charles Messier. Determine in which constellation the object lies. Now, find the constellation in the sky. If you do not recognize the constellation on sight, consult a planisphere. The planisphere gives an all-sky view and shows which constellations are visible on a given night at a given time. Now look at your star chart and find the brightest star in the constellation that is near the object that you are trying to find. Using the finder scope, point the telescope at this star and center it on the crosshairs Next, look again at the star chart and find another suitably bright star near the bright star currently centered in the finder. Keep in mind that the field of view of the finder scope is between 5° - 7°, so you should choose a star that is no more than 7° from the first star, if possible. Move the telescope slightly, until the telescope is centered on the new star. Continue using stars as guideposts in this way until you are the approximate position of the object you are trying to find. Look in the telescope’s eyepiece, and the object should be somewhere within the field of view. If it’s not, sweep the telescope carefully around the immediate vicinity until the object is found. If you have trouble finding the object, start the starhop again from the brightest star near the object you wish to view. This time, be sure the stars indicated on the star chart are in fact the stars you are centering in the finder scope and telescope eyepiece. Remember the telescope and the finder scope will give you inverted images (unless you are using a correct image finder scope), keep this in mind when you are starhopping from star to star. Observing Hint: Always use your lowest powered eyepiece in your telescope when starhopping . This will give you the widest possible field of view.
For land viewing, it’s best to stick with low power eyepieces that yield a magnification under 100x. At higher powers, images rapidly lose sharpness and clarity due to “heat waves” caused by Sun-heated air. Remember to aim well clear of the Sun, unless the front of the telescope is fitted with a professionally made solar filter and the finder scope is removed or covered with foil or some other completely opaque material. Many Orion telescopes are capable of focusing on objects that are quite close, so you can view fine details of objects that are nearby. Try focusing on a flower or insect at close distance to enter a normally unseen microscopic world. Check the specifications on the product web page or instruction manual for your Orion scope. Observing hint: If the object is too close to focus. You may be able to use an extension tube that allows the eyepiece to move further back as you focus closer. Try lifting the eyepiece out of the holder as you look. If it focuses in about an inch or two, you can purchase an eyepiece extension tube. For more detailed information on this topic see our Learning Center article: Choosing Eyepieces
We carry correct-image prism diagonals which provide right-side up non-reversed images in refractor and cassegrain telescopes. It is not possible to correct the image orientation in a reflector telescope.
Any quality optical lens cleaning tissue and optical lens cleaning fluid specifically designed for multi-coated optics can be used to clean the exposed lenses of your eyepieces or finder scope. Never use regular glass cleaner or cleaning fluid designed for eyeglasses. Before cleaning with fluid and tissue, blow any loose particles off the lens with a blower bulb or compressed air. Then apply some cleaning fluid to a tissue, never directly on the optics. Wipe the lens gently in a circular motion, then remove any excess fluid with a fresh lens tissue. Oily finger-prints and smudges may be removed using this method. Use caution; rubbing too hard may scratch the lens. On larger lenses, clean only a small area at a time, using a fresh lens tissue on each area. Never reuse tissues.
As a general rule, telescopes should be allowed to cool down (or warm up) before they are used. If you bring optics from a warm air to cold air (or vice versa) without giving it time to reach thermal equilibrium, your telescope will give you distorted views. Allow your telescope 30 minutes to an hour to reach the temperature of the outdoors before using. When brining your telescope from cool temperatures to warm temperatures, leave any protective caps off until the telescope has warmed-up to prevent condensation. Storing your telescope in the garage or shed where the temperature is closer to the outside temperature will reduce cool down times.
For Northern Hemisphere observers, approximate polar alignment is achieved by pointing the mount’s R.A. axis at the North Star, or Polaris. It lies within 1° of the north celestial pole (NCP), which is an extension of the Earth’s rotational axis out into space. Stars in the Northern Hemisphere appear to revolve around Polaris. To find Polaris in the sky, look north and locate the pattern of the Big Dipper. The two stars at the end of the “bowl” of the Big Dipper point right to Polaris. Observers in the Southern Hemisphere aren’t so fortunate to have a bright star so near the south celestial pole (SCP). The star Sigma Octantis lies about 1° from the SCP, but it is barely visible with the naked eye (magnitude 5.5). For general visual observation, an approximate polar alignment is sufficient: 1. Level the equatorial mount by adjusting the length of the three tripod legs. 2. Loosen one of the latitude adjusting T-bolts and tighten the other to tilt the mount until the pointer on the latitude scale is set at the latitude of your observing site. This may vary depending on the mount, some have one bolt and a tightening screw instead. If you don’t know your latitude, consult a geographical atlas to find it. For example, if your latitude is 35° North, set the pointer to +35. The latitude setting should not have to be adjusted again unless you move to a different viewing location some distance away. 3. Loosen the Dec. lock lever and rotate the telescope optical tube until it is parallel with the R.A. axis. The pointer on the Dec. setting circle should read 90°. Retighten the Dec. lock lever. 4. Move the tripod so the telescope tube (and R.A. axis) points roughly at Polaris. If you cannot see Polaris directly from your observing site, consult a compass and rotate the tripod so the telescope points north. Using a compass is a less desirable option, a compass points about 16° away from true north and requires you to compensate foe accurate polar alignment. The equatorial mount is now approximately polar-aligned for casual observing. More precise polar alignment is required for astrophotography and for use of the manual setting circles. From this point on in your observing session, you should not make any further adjustments to the latitude of the mount, nor should you move the tripod. Doing so will undo the polar alignment. The telescope should be moved only about its R.A. and Dec. axes.
This procedure is complicated and it is not required for casual observing, but here it goes . . . Remove the cover cap from the front opening in the R.A. axis of the telescope mount. Look through the polar finder at a distant object. Focus the polar finder so that the images and reticle are sharp by rotating the eyepiece end of the finder. Notice that the reticle pattern consists of a crosshair with a circle around the middle. On the circumference of this circle is a tiny circle; this is where Polaris will be placed for accurate polar alignment once the finder is properly aligned. Alignment of the polar finder is best done during the day, before going out into the field at night. Aligning the polar axis finder scope so that it will accurately point at the true north pole is a two-step procedure. First, the polar finder must be rotated in its housing so that the small circle in which Polaris will be placed in is in the proper initial position. Next, the polar axis finder must be adjusted so that it points directly along the mount’s R.A. axis. 1. Loosen the R.A. setting circle lock thumb screw, located just above the R.A. setting circle. Rotate the R.A. setting circle until the line above the “0” on the setting circle lines up with the pointed indicator that is cast into the mount. Retighten the thumbscrew. 2. Rotate the date circle until the “0” line on the meridian off-set scale lines up with the time meridian indicator mark. The meridian offset scale is printed on the inner circumference of the date circle, and is labeled “E20” to “W20”. The time meridian indicator mark is an engraved line on the exterior of the polar finder’s housing. It is on the “ring” of the housing that is closest to the date circle. 3. The R.A. setting circle is labeled in hours, from “0” to “23” (military time). For Northern Hemisphere observers, refer to the top numbers on the setting circle. Each small line represents 10 minutes of R.A. The date circle is labeled from “1” to “12”, with each number representing a month of the year (“1” is January, “2” is February, etc.). Each small line represents a two-day increment. 4. Loosen the R.A. lock lever and rotate the mount about the R.A. axis until the March 1 indicating mark (the long line between the “2” and the “3”) on the date circle lines up with the 4 PM mark (the long line above the “16”) on the R.A. setting circle. You may find it convenient to remove both the counterweights and the telescope optical tube to do this. 5. Now, loosen the three thumbscrews on the polar finder housing and rotate the polar finder so the small circle where Polaris will be centered is located straight down from the intersection of the crosshairs. Retighten the thumbscrews. The polar axis finder scope is now properly set in its initial position. Next, you must align it so that it is exactly parallel to the mount’s R.A. axis. 6. Look through the polar finder at a distant object (during the day) and center it in the crosshairs. You may need to adjust the latitude adjustment T-bolts and the tripod position to do this. 7. Rotate the mount 180° about the R.A. axis. Again, it may be convenient to remove the counterweights and optical tube first. 8. Look through the polar finder again. Is the object being viewed still centered on the crosshairs? If it is, then no further adjustment is necessary. If not, then look through the polar finder while rotating the mount about the R.A. axis. You will notice that the object you have previously centered moves in a circular path. Use the three thumbscrews on the housing to redirect the crosshairs of the polar finder to the apparent center of this circular path. Repeat this procedure until the position that the crosshairs point to does not rotate off-center when the mount is rotated in R.A. Once this is accomplished, retighten the thumbscrews. The polar axis finder scope is now ready to be used. When not in use, replace the plastic protective cover to prevent the polar finder from getting bumped, which could knock it out of alignment.
Beginners occasionally experience some confusion about how to point the telescope overhead or in other directions. At the zenith: You want to view an object that is directly overhead, at the zenith. DO NOT make any adjustment to the latitude adjustment T-bolts. That will spoil the mount’s polar alignment. Remember, once the mount is polar aligned, the telescope should be moved only on the R.A. and Dec. axes. To point the scope overhead, first loosen the R.A. lock lever and rotate the telescope on the R.A. axis until the counterweight shaft is horizontal (parallel to the ground). Then loosen the Dec. lock lever and rotate the telescope until it is pointing straight overhead. The counterweight shaft is still horizontal. Then retighten both lock levers. Directly north at an object that is nearer to the horizon than Polaris: You can’t do it with the counterweight down. You have to rotate the scope in R.A. so that the counterweight shaft is positioned horizontally. Then rotate the scope in Dec. so it points to where you want it near the horizon. Directly south: The counterweight shaft should again be horizontal. Then you simply rotate the scope on the Dec. axis until it points in the south direction. East or west: To point the telescope to the east or west, or in other directions, you rotate the telescope on its R.A. and Dec. axes. Depending on the altitude of the object you want to observe, the counterweight shaft will be oriented somewhere between vertical and horizontal. Another hint: On some smaller scopes the RA slow-motion shaft can get in the way of some orientations. If this occurs, simply remove the slow-motion knobs and re-attach to the other side of the RA axis.
When you observe a celestial object through the telescope, you’ll see it drift slowly across the field of view. To keep it in the field, if your equatorial mount is polar-aligned, just turn the R.A. slow-motion control. The Dec. slow-motion control is not needed for tracking, but may be required to center the object. Objects will appear to move faster at higher magnifications, because the field of view is narrower. A DC motor drive system can be mounted on all Orion equatorial mounts to provide hands-free tracking. Motor drive systems are typically offered as an optional accessory. Objects will then remain stationary in the field of view without any manual adjustment of the R.A. slow-motion control. A dual-axis motor drive is necessary for astrophotography.
One of the benefits of a telescope on an equatorial mount is that it can accept an electronic motor drive to “track” the motion of the stars. Without a drive an object will drift out of the field of view (due to the earth’s rotation). And, while every equatorial mount come with “slow motion” control controls that allow you to reposition the scope by hand to keep objects in view, an electronic drive does this automatically by exactly countering the rate of Earth’s rotation. It lets you observe that planet or nebula continuously without having to manually tweak the telescope’s potion again and again. There are two basic types of electronic drive systems; single axis and dual axis. A single axis drive is a single motor that couples to the R.A. axis of the equatorial mount and drives the scope from East to West to provides basic star tracking. For general astronomical observing, a single axis drive is usually sufficient. A dual axis drive motorizes both axes of motion of the equatorial mount. It provides the basic tracking function as well as fine control of the telescope position in any direction. A dual axis system comes in especially handy for observing as high powers and is a must for long-term astrophotography. So, why not let your telescope do the driving!
The setting circles on an equatorial mount enable you to locate celestial objects by their “celestial coordinates”. Every object resides in a specific location on the “celestial sphere”. That location is denoted by two numbers: its right ascension (R.A.) and declination (Dec.). In the same way, every location on Earth can be described by its longitude and latitude. R.A. is similar to longitude on Earth, and Dec. is similar to latitude. The R.A. and Dec. values for celestial objects can be found in any star atlas or star catalog. The R.A. setting circle is scaled in hours, from 1 through 24, with small marks in between representing 10 minute increments (there are 60 minutes in 1 hour of R.A.). The upper set of numbers apply to viewing in the Northern Hemisphere, while the numbers below them apply to viewing in the Southern Hemisphere. The Dec. setting circle is scaled in degrees, with each mark representing 2° increments. Values of Dec. coordinates range from +90° to -90°. The 0° mark indicates the celestial equator. When the telescope is pointed north of the celestial equator, values of the Dec. setting circle are positive, while when the telescope is pointed south of the celestial equator, values of the Dec. setting circle are negative. So, the coordinates for the Orion Nebula listed in a star atlas will look like this: R.A. 5h 35.4m Dec. -5° 27' That’s 5 hours and 35.4 minutes in right ascension, and -5 degrees and 27 arc-minutes in declination (there are 60 arc-minutes in 1 degree of declination). Before you can use the setting circles to locate objects, the mount must be well polar aligned, and the R.A. setting circle must be calibrated. The Dec. setting circle has been calibrated at the factory, and should read 90° whenever the telescope optical tube is parallel with the R.A. axis. Click here for information on calibrating the RA Axis. (Insert a Link)
Look up in a star atlas the coordinates of an object you wish to view. 1. Loosen the Dec. lock lever and rotate the telescope until the Dec. value from the star atlas matches the reading on the Dec. setting circle. Remember that values of the Dec. setting circle are positive when the telescope is pointing north of the celestial equator (Dec. = 0°), and negative when the telescope is pointing south of the celestial equator. Retighten the lock lever. 2. Loosen the R.A. lock lever and rotate the telescope until the R.A. value from the star atlas matches the reading on the R.A. setting circle. Remember to use the upper set of numbers on the R.A. setting circle. Retighten the lock lever. The lower set is for the Southern Hemisphere. Most setting circles are not accurate enough to put an object dead-center in the telescope’s eyepiece, but they should place the object somewhere within the field of view of the finder scope, assuming the equatorial mount is accurately polar aligned. Use the slow-motion controls to center the object in the finder scope, and it should appear in the telescope’s field of view. The R.A. setting circle must be re-calibrated every time you wish to locate a new object. Do so by calibrating the setting circle for the centered object before moving on to the next one.
Most setting circles are not accurate enough to put an object dead-center in the telescope’s eyepiece, but they should place the object somewhere within the field of view of the finder scope, assuming the equatorial mount is level and accurately polar-aligned. Use the slow-motion controls to center the object in the finder scope, and it should appear in the telescope’s field of view. The R.A. setting circle must be re-calibrated every time you wish to locate a new object. Do so by calibrating the setting circle for the centered object before moving on to the next one.
1. Identify a bright star in the sky near the celestial equator (Dec. = 0°) and look up its coordinates in a star atlas. 2. Loosen the R.A. and Dec. lock levers on the equatorial mount, so the telescope optical tube can move freely. 3. Point the telescope at the bright star whose coordinates you know. Lock the R.A. and Dec. lock levers. Center the star in the telescope’s field of view with the slow-motion control cables. 4. Loosen the R.A. setting circle lock thumbscrew (if there is a thubmscrew, some RA circles don’t have a set screw they use friction), this will allow the setting circle to rotate freely. 5. Rotate the setting circle until the arrow under the thumbscrew indicates the R.A. coordinate listed in the star atlas for the object. 6. Do not retighten the thumbscrew when using the R.A. setting circles for finding objects; the thumbscrew is only needed for polar alignment using the polar axis finder scope.
Here are some things to check: 1. Is the telescope properly balanced? The motor provides only limited torque, so if the telescope is not balanced on both the right ascension and declination axes, the imbalance may put stress on the motor and inhibit the smooth movement of the telescope. 2. Is the coupling thumbscrew on the motor’s drive coupling tight against the R.A. shaft on the equatorial telescope mount? If it is loose, the R.A. shaft may not be turning at the same rate as the motor coupling, or at all. Make sure the thumbscrew is tight against the flat spot on the shaft. If it’s not on the flat spot, even when very tight, it can slip. You can use the position of the set screw on the opposite side (the slow-motion knob) to determine where the flat spot is on the motor side. 3. The torque needed to rotate the R.A. worm gear may be set too high. Careful attention must be paid to the amount of torque needed to rotate the R.A. worm gear. If the amount of torque seems great (the R.A. slow-motion control is hard to turn), the motor may be hindered and will provide unreliable tracking (or the motor could suffer damage). Diagrams and troubleshooting the torque of the R.A. worm gear are included in the Orion motor drive instruction manuals.
The moon moves at a slightly slower rate from East to West than sidereal rate, so the motor speed needs to be reduced. If it North or South, the polar alignment should be checked.
Once basic Moon photography has been mastered, it’s time to get images of the planets. This type of astrophotography also works to get highly magnified shots of the Moon. In addition to the T-ring, you will need a Universal 1.25"" Camera Adapter. A motor drive system (single or dual axis) is also required. This is because a longer exposure is necessary, which would cause the image to blur if no motor drive was used for tracking. The equatorial mount must be accurately polar aligned, too. As before, connect the T-ring to your camera. Before connecting the Universal camera adapter to the T-Ring, an eyepiece must be inserted and locked into the body of the Universal camera adapter. Start by using a medium-low power eyepiece (about 25mm); you can increase the magnification later with a high-power eyepiece. Then connect the entire camera adapter, with eyepiece inside, to the T-Ring. Insert the whole system into the telescope’s focuser drawtube and secure firmly with the thumbscrews. Aim the telescope at the planet (or Moon) you wish to shoot. The image will be highly magnified, so you may need to use the finder scope to center it within the camera’s viewfinder. Turn the motor drive on. Adjust the telescope’s focuser so that the image appears sharp in the camera’s viewfinder. The camera’s shutter is now ready to be opened. A remote shutter release or shutter timer must be used or the image will be blurred beyond recognition. Try exposure times between 1 and 10 seconds, depending upon the brightness of the planet to be photographed and the ISO of the film being used. We’ve also seen good digital snapshots of images taken through the telescope’s eyepiece with the SteadyPix adapter.
The Moon and planets are interesting targets for the budding astrophotographer, but what next? Literally thousands of deep-sky objects can be captured on film with a type of astrophotography called “piggybacking”. The basic idea is that the camera with its own camera lens attached rides on top of the main telescope. The telescope and camera both move with the rotation of the Earth when the mount is polar aligned and the motor drive is engaged. This allows for a long exposure through the camera without having the object or background stars blurred. In addition to the motor drive (dual-axis), and illuminated reticle eyepiece is also needed. The T-ring and camera adapter are not needed, since the camera is exposing through its own lens. Any camera lens with a focal length between 35mm and 400mm is appropriate. On the top of one of the tube rings is a piggyback camera adapter. This is the black knob with the threaded shaft protruding through it. The tube ring with the piggyback adapter should be closest to the open end of the telescope tube. Remove the tube rings from the equatorial mount and swap their position if necessary. Now, connect the camera to the piggyback adapter. There should be a 1/4"-20 mounting hole in the bottom of the camera’s body. Thread the protruding shaft of the piggyback adapter into the 1/4"-20 mounting hole in the camera a few turns. Position the camera so it is parallel with the telescope tube and turn the knurled black knob of the piggyback adapter counter-clockwise until the camera is locked into position. Aim the telescope at a deep-sky object. It should be a fairly large deep-sky object, as the camera lens will likely have a wide field of view. Check to make sure that the object is also centered in the camera’s viewfinder. Turn the motor drive on. Now, look into the telescope’s eyepiece and center the brightest star within the field of view. Remove the eyepiece and insert the illuminated reticle eyepiece into the focuser draw-tube. Turn the eyepiece’s illuminator on (dimly!). Re-center the bright star (guide star) on the crosshairs of the reticle eyepiece. Check again to make sure that the object to be photographed is still centered within the camera’s field of view. If it is not, re-center it by repositioning the camera on the piggy-back adapter, or by moving the main telescope. If you move the main telescope, then you will need to re-center another guide star on the illuminated eyepiece’s crosshairs. Once the object is centered in the camera and a guide star is centered in the reticle eyepiece, you’re ready to shoot. While exposing through the camera lens, you will need to monitor the accuracy of the mount’s tracking by looking through the illuminated reticle eyepiece in the main telescope. If the guide star drifts from its initial position, then use the hand controller of the motor drive to “move” the guide star back to the center of the crosshairs. Any drifting along the Dec. axis is a result of improper polar alignment, so if the guide star drifts greatly in Dec., the mount may need to be polar aligned more accurately. When the exposure is complete, unlock the shutter release cable and close the camera’s shutter. A few hints from Orion astrophographers: Film speed can be anything from 100-1600, slower film yields less “grainy” results, but requires longer exposure times. Older manual cameras work better for piggyback photography than electronic cameras. Most lenses are sharpest closed down one stop from full open. Astrophotography can be enjoyable and rewarding, as well as frustrating and time-consuming. Start slowly and consult outside resources, such as books and magazines, for more details about astrophotography. Remember. . . have fun!
By attaching a camera body to a telescope, in effect using the scope as a telephoto lens, you can take striking photographs of the Sun. Only attempt this if the telescope is equipped with the proper solar filter. Solar filters are coated to a neutral density of 5, which reduces the light about 100,000 times. Depending on the aperture and focal length of your telescope and “seeing” conditions, you will need to experiment to find the best exposure time for your equipment. We recommend starting with an ISO rating of around 400. At prime focus, start with an exposure of about 1/250 second. Experiment with different shutter speeds. When using higher magnifications, longer exposures will generally be necessary. If you are a beginner in astrophotography and need further information, there are books available that cover this subject completely. Do not be discouraged if your first attempts at solar photography are less than desired. The Sun is very difficult to photograph because of poorer “seeing” conditions caused by unavoidable heat currents associated with daytime viewing. The highest possible resolution for any land-based telescope, regardless of location, is about 1 arc second. Ideal seeing for any location will be available less than 5% of the time. It may be some consolation to consider that your results could equal those at professional observatories, as larger apertures and location have little, if any, advantage. During bad seeing conditions, it may help to “stop down” apertures over 5" with an off-axis mask.
One of the problems with a solar filter on a telescope is that it’s a bit tricky to aim it at the sun. You can’t look through the finder to point the scope or you’ll cause injury to your eye. So, cap off or remove the finder. Also, because with the very dark filter on the front if the sun is slightly outside the field of view of the eyepiece you’ll see pitch blackness in the field. With the solar filter properly mounted, try looking at the shadow of the optical tube on the ground, move the tube until the shadow is at a minimum. You’ll be pointed at the sun, or at least close enough to find it with a little sweeping and a low-power eyepiece to bring it into view. It can be difficult, even with the shadow method. An other trick to try after you’ve got it close with the shadow if your still not having any luck getting the sun in the field. . . take the eyepiece out of the focuser. Then look into the focuser...you won’t see an image but when the sun gets close you’ll see a flicker of brightness coming through the mirrors. Then pop the eyepiece back in and you should have it.
|
Let our Smart Buy Advisor help with your decision!
|